2-7.
SERVICE TO AN/UAS-11 EQUIPMENT SET (CONT)
(Sheet 2 of 6)
E.
Check that coolant cartridge (5) is installed (para 3-6).
F.
Turn actuator (6) to ON position (fully counterclockwise).
G.
Check to see that coolant pressure gage (7) indicates between 1,000 and
6,000 PSI. If not, replace coolant cartridge (para 3-6).
Be sure lens cleaning kit bag (8) is complete with cotton pads (9),
H.
bottle (10) and socket-head screw key (11). The bottle (10) is shipped
empty and must be filled with cleaning solution (Item 4, Appendix D).
GO TO NEXT PAGE
2-12